1,540 research outputs found

    Characteristics and energy dependence of recurrent galactic cosmic-ray flux depressions and of a forbush decrease with LISA Pathfinder

    Get PDF
    The final publication is available at IOS Press through http://dx.doi.org/10.3847/1538-4357/aaa774Galactic cosmic-ray (GCR) energy spectra observed in the inner heliosphere are modulated by the solar activity, the solar polarity and structures of solar and interplanetary origin. A high counting rate particle detector (PD) aboard LISA Pathfinder, meant for subsystems diagnostics, was devoted to the measurement of GCR and solar energetic particle integral fluxes above 70 MeV n-1 up to 6500 counts s-1. PD data were gathered with a sampling time of 15 s. Characteristics and energy dependence of GCR flux recurrent depressions and of a Forbush decrease dated 2016 August 2 are reported here. The capability of interplanetary missions, carrying PDs for instrument performance purposes, in monitoring the passage of interplanetary coronal mass ejections is also discussed.Peer ReviewedPreprin

    Richmond City Health District (RCHD), Bon Secours Richmond City Hospital (RCH), and Virginia Commonwealth Universities (VCU) Department of Health Behavior Policy (HBP): Partnering with Community Health Workers (CHW) to Improve Community Health Outcomes and Reduce Emergency Department (ED) Use

    Get PDF
    Background: Frequent ED users (5%) are sicker, poorer, not satisfied with the health system and cost 20% of total ED charges. Objective: A pilot study of feasibility of partnering with CHW to improve health knowledge and outcomes and reduce ED use in low income community. Methods: RCH ED utilizers were randomized to intervention and control groups. CHW contacted intervention group within 10 days of ED visit, surveyed about access to care, healthy living, and knowledge about chronic disease, and offered education, referrals to insurance and social and economic support. ED utilization and cost were recorded for all patients for 6 months. Preventable ED visits were classified according to Johnston et al1 and high utilizers have 2+ ED visits. Intervention and control characteristics and ED utilizations and cost were described and compared using t-tests, ANOVA, and Chi-square at alpha=0.1. Adjusted analyses were performed using linear and logistic regressions. Results: 91 and 61 randomized to intervention and control with 29 and 23 high utilizers respectively. Drop-in percent of patients with all and preventable ED visits was higher among intervention (12 and 17 percentage points, respectively). 65% of the total ED cost is preventable in the pre-intervention period. That dropped by 17 and 7% in intervention period among the intervention and control groups. The intervention estimated cost savings were $120K. Intervention group had significant improvement in self-reported general health, regular exercise, understanding of health benefits and chronic disease. Conclusions: hospital, academic, and CHW partnership reduces ED utilization and cost and improves health.https://scholarscompass.vcu.edu/gradposters/1116/thumbnail.jp

    Increasing the bandwidth of resonant gravitational antennas: The case of Explorer

    Full text link
    Resonant gravitational wave detectors with an observation bandwidth of tens of hertz are a reality: the antenna Explorer, operated at CERN by the ROG collaboration, has been upgraded with a new read-out. In this new configuration, it exhibits an unprecedented useful bandwidth: in over 55 Hz about its frequency of operation of 919 Hz the spectral sensitivity is better than 10^{-20} /sqrt(Hz) . We describe the detector and its sensitivity and discuss the foreseable upgrades to even larger bandwidths.Comment: 4 pages- 4 figures Acceted for publication on Physical Review Letter

    Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K

    Get PDF
    We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and read out by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output sygnal. We measured a peak strain sensitivity of 1.5⋅10−20Hz−1/21.5\cdot 10^{-20} Hz^{-1/2} at 2942.9 Hz. A strain sensitivity of better than 5⋅10−20Hz−1/25\cdot 10{-20}Hz{-1/2} has been obtained over a bandwidth of 30 Hz. We expect an improvement of more than one order of magnitude when the detector will operate at 50 mK. Our results represent the first step towards the development of an ultracryogenic omnidirectional detector sensitive to gravitational radiation in the 3kHz range.Comment: 8 pages, 5 figures, submitted to Physical Review

    An investigation of the RWPE prostate derived family of cell lines using FTIR spectroscopy

    Get PDF
    Interest in developing robust, quicker and easier diagnostic tests for cancer has lead to an increased use of Fourier transform infrared (FTIR) spectroscopy to meet that need. In this study we present the use of different experimental modes of infrared spectroscopy to investigate the RWPE human prostate epithelial cell line family which are derived from the same source but differ in their mode of transformation and their mode of invasive phenotype. Importantly, analysis of the infrared spectra obtained using different experimental modes of infrared spectroscopy produces similar results. The RWPE family of cell lines can be separated into groups based upon the method of cell transformation rather than the resulting invasiveness/aggressiveness of the cell line. The study also demonstrates the possibility of using a genetic algorithm as a possible standardised pre-processing step and raises the important question of the usefulness of cell lines to create a biochemical model of prostate cancer progression

    Dark Matter searches using gravitational wave bar detectors: quark nuggets and newtorites

    Get PDF
    Many experiments have searched for supersymmetric WIMP dark matter, with null results. This may suggest to look for more exotic possibilities, for example compact ultra-dense quark nuggets, widely discussed in literature with several different names. Nuclearites are an example of candidate compact objects with atomic size cross section. After a short discussion on nuclearites, the result of a nuclearite search with the gravitational wave bar detectors Nautilus and Explorer is reported. The geometrical acceptance of the bar detectors is 19.5 m2\rm m^2 sr, that is smaller than that of other detectors used for similar searches. However, the detection mechanism is completely different and is more straightforward than in other detectors. The experimental limits we obtain are of interest because, for nuclearites of mass less than 10−510^{-5} g, we find a flux smaller than that one predicted considering nuclearites as dark matter candidates. Particles with gravitational only interactions (newtorites) are another example. In this case the sensitivity is quite poor and a short discussion is reported on possible improvements.Comment: published on Astroparticle Physics Sept 25th 2016 replaced fig 1

    Reception frequency bandwidth of a gravitational resonant detector with optical readout

    Full text link
    A gravitational resonant bar detector with a large scale Fabry-Perot cavity as an optical read out and a mechanical displacement transformer is considered. We calculate, in a fully analytical way, the final receiver bandwidth in which the potential sensitivity, limited only by the bar thermal noise, is maintained despite the additional thermal noise of the transformer and the additive noise of the optical readout. We discuss also an application to the OGRAN project, where the bar is instrumented with a 2m long FP cavity.Comment: 16 pages + 3 figures. Accepted for publicationi in Class. Quantum Gra

    Quark nuggets search using 2350 Kg gravitational waves aluminum bar detectors

    Get PDF
    The gravitational wave resonant detectors can be used as detectors of quark nuggets, like nuclearites (nuclear matter with a strange quark). This search has been carried out using data from two 2350 Kg, 2 K cooled, aluminum bar detectors: NAUTILUS, located in Frascati (Italy), and EXPLORER, that was located in CERN Geneva (CH). Both antennas are equipped with cosmic ray shower detectors: signals in the bar due to showers are continuously detected and used to characterize the antenna performances. The bar excitation mechanism is based on the so called thermo-acoustic effect, studied on dedicated experiments that use particle beams. This mechanism predicts that vibrations of bars are induced by the heat deposited in the bar from the particle. The geometrical acceptance of the bar detectors is 19.5 m2\rm m^2 sr, that is smaller than that of other detectors used for similar searches. However, the detection mechanism is completely different and is more straightforward than in other detectors. We will show the results of ten years of data from NAUTILUS (2003-2012) and 7 years from EXPLORER (2003-2009). The experimental limits we obtain are of interest because, for nuclearites of mass less than 10−410^{-4} grams, we find a flux smaller than that one predicted considering nuclearites as dark matter candidates.Comment: presented to the 33rd International Cosmic Ray Conference Rio de Janeiro 201

    Superconducting cavity transducer for resonant gravitational radiation antennas

    Full text link
    Parametric transducers, such as superconducting rf cavities, can boost the bandwidth and sensitivity of the next generation resonant antennas, thanks to a readily available technology. We have developed a fully coupled dynamic model of the system "antenna--transducer" and worked out some estimates of signal--to--noise ratio and the stability conditions in various experimental configurations. We also show the design and the prototype of a rf cavity which, together with a suitable read--out electronic, will be used as a test bench for the parametric transducer.Comment: 7 pages, 3 eps figures. Presented at the 6th Amaldi Conference on Gravitational Waves (2005). Accepted for publication in Journal of Physics: Conference Serie

    MiniGRAIL progress report 2004

    Get PDF
    The MiniGRAIL detector was improved. The sphere was replaced by a slightly larger one, having a diameter of 68 cm (instead of 65 cm), reducing the resonant frequency by about 200 Hz to around 2.9 kHz. The last four masses of the attenuation system were machined to increase their resonant frequency and improve the attenuation around the resonant frequency of the sphere. In the new sphere, six holes were machined on the TIGA positions for easy mounting of the transducers. During the last cryogenic run, two capacitive transducers and a calibrator were mounted on the sphere. The first transducer was coupled to a double-stage SQUID amplifier having a commercial quantum design SQUID as a first stage and a DROS as a second stage. The second transducer was read by a single-stage quantum design SQUID. During the cryogenic run, the sphere was cooled down to 4 K. The two-stage SQUID had a flux noise of about 1.6 ÎŒ0 Hz−1/2. The detector was calibrated and the sensitivity curve of MiniGRAIL was determined
    • 

    corecore